 |
Heat Pumps
|
|
QUICK CONNECT
10 Years Parts / 1 Year Labor *
* Extended Service Contracts Available
* To receive 10-year Parts Limited Warranty, online
registration of unit must be completed within 60 days of installation.
|
|
SPLIT SYSTEM 13 S.E.E.R. HEAT PUMPS
- Meets New Federal Mandated High Efficiency Standards
- Energy Saving Heat Pump Technology
- State of the Art Compressor Technology
- High Humidity Control Performance
- Positive Seal, Brass Quick Connect Refrigerant Connections
- Connection Available in Sweat Fit
- 100% Corrosion Resistant Copper Tube Coils
- "Hail Guard" Design is Factory Installed Offering Increased Severe Weather Durability
- Durable Powder Coat Finish
|
| Nominal Ton Capacity |
Condenser SKU |
Microchannel Condenser-Description |
Weight Lbs. |
Unit Dimensions LxWxH |
Pad Part Number |
Lineset Sizes |
Matching Indoor Coil |
| 2.0 | 14H41324 | Condenser-HP QC 2.0 T 13S R410A | 184 | 34"x34"x32" | 1134343D | 3/8" x 3/4" | 1836Q4A |
| 2.5 | 14H41330 | Condenser-HP QC 2.5 T 13S R410A | 196 | 34"x34"x36" | 1134343D | 3/8" x 3/4" | 1843Q4A |
| 3.0 | 14H41336 | Condenser-HP QC 3.0 T 13S R410A | 208 | 34"x34"x40" | 1134343D | 3/8" x 7/8" | 1843Q4A |
| 3.5 | 14H41342 | Condenser-HP QC 3.5 T 13S R410A | 208 | 34"x34"x40" | 1134343D | 3/8" x 7/8" | 1843Q4A 1854Q4A |
| 4.0 | 14H41348 | Condenser-HP QC 4.0 T 13S R410A | 275 | 34"x34"x40" | 1134343D | 3/8" x 7/8" | 1854Q4A |
**Coil will not fit in gas furnaces or electric furnaces with coil cabinets
Note: 6918.5011 Time Delay Relay Required on ALL Manufactured Housing Electric and Oil Furnaces
* 3500.7901 Blower Required on EB(XX) Furnaces
* 7900.7751 Blower Required on DGAA, DFAA Furnaces
* Refer to ARI directory listings
|
|
|
|
SWEAT FIT
10 Years Parts / 30 Days Labor *
* Extended Service Contracts Available
* To receive 10-year Parts Limited Warranty, online
registration of unit must be completed within 60 days of installation.
|
|
SPLIT SYSTEM 13 S.E.E.R. HEAT PUMPS
- Accumulator regulates differing refrigeration needs of heating and cooling cycles
- Coated-aluminum fins with copper tube coils look great and provide durable, efficient operation
- Compressor is protected from high pressure and temperature for durability
- High-pressure relief valve and solid core filter drier extends life of compressor
- Reversing valve regulates change from cooling to heating cycle
- Filter drier provides extra protection to the refrigerant system from moisture, dirt and other contaminants
|
| Nominal Ton Capacity |
Condenser SKU |
Microchannel Condenser-Description |
Weight Lbs. |
Unit Dimensions LxWxH |
Pad Part Number |
Lineset Sizes |
Matching Indoor Coil |
| 1.5 | GHGD18S41S | Condenser-HP SF 1.5T 13SEER R410 | 172 | 34"x34"x28" | 1134343D | 3/8" x 3/4" | 1830S4A |
| 2.0 | GHGD24S41S | Condenser-HP SF 2.0T 13SEER R410 | 184 | 34"x34"x32" | 1134343D | 3/8" x 3/4" | 1836S4A |
| 2.5 | GHGD30S41S | Condenser-HP SF 2.5T 13SEER R410 | 196 | 34"x34"x36" | 1134343D | 3/8" x 3/4" | 1843S4A |
| 3.0 | GHGD36S41S | Condenser-HP SF 3.0T 13SEER R410 | 208 | 34"x34"x40" | 1134343D | 3/8" x 3/4" | 1843S4A |
| 3.5 | GHGD42S41S | Condenser-HP SF 3.5T 13SEER R410 | 208 | 34"x34"x40" | 1134343D | 3/8" x 7/8" | 1843S4A |
| 4.0 | GHGD48S41S | Condenser-HP SF 4.0T 13SEER R410 | 275 | 34"x34"x40" | 1134343D | 3/8" x 7/8" | 1854S4A |
| 5.0 | GHGD60S41S | Condenser-HP SF 5.0T 13SEER R410 | 280 | 34"x34"x40" | 1134343D | 3/8" x 7/8" | 1856S4A** |
| ** Fits Nordyne Electric Furnace only |
**Coil will not fit in gas furnaces or electric furnaces with coil cabinets
Note: 6918.5011 Time Delay Relay Required on ALL Manufactured Housing Electric and Oil Furnaces
* 3500.7901 Blower Required on EB(XX) Furnaces
* 7900.7751 Blower Required on DGAA, DFAA Furnaces
* Refer to ARI directory listings
|
|
|
|
 |
|
 |